濟南活動板房安裝的技術性關鍵點是近期很多好朋友會問到我們小編的一個常見問題,那小編話不多說直奔主題:講述一下活動板房安裝的技術性關鍵點。大家如果感興趣可以收藏本篇文章抽時間詳細閱讀閱讀。那接下來跟隨小編了解一下這篇文章吧!
The technical key point of Jinan movable plank house installation is a common question that many good friends will ask our Xiaobian recently. The Xiaobian doesn't say much and goes straight to the theme: tell us about the technical key points of movable plank house installation. If you are interested, you can collect this article and take time to read it in detail. Then follow Xiaobian to learn about this article!
1.活動板房的擋土板(屋面、板墻)應無顯著形變和毀壞;固定不動地腳螺栓、防潮密封圈、金屬材料密封圈、尼龍板管等。詳細且連接靠譜;密封劑齊全有效。
1. The earth retaining plate (roof and plate wall) of the movable plank house shall be free from significant deformation and damage; Fixed anchor bolts, moisture-proof sealing rings, metal sealing rings, nylon plate pipes, etc. Detailed and reliable connection; The sealant is complete and effective.
2.活動板房屋面安裝應穩(wěn)定,挑檐應豎直,板的鋼筋搭接方位應恰當一致。
2. The roof of the movable plank house shall be installed stably, the cornice shall be vertical, and the overlapping direction of the reinforcement of the slab shall be appropriate and consistent.
3.粘附板墻應安裝恰當,表層光潔。預埋件板墻安裝應穩(wěn)定,左右鋼筋搭接選用企口接頭,兩側板往下鋼筋搭接,鋼筋搭接尺寸不小于15mm。
3. The adhesive board wall shall be properly installed and the surface shall be smooth. The embedded parts shall be installed stably on the plate and wall. The left and right reinforcement shall be overlapped with tongue and groove joints, and the lower reinforcement of the plates on both sides shall be overlapped. The overlapping size of the reinforcement shall not be less than 15mm.
4.活動板房電氣設備布線應應用PVC管(槽),布線應工整美觀大方;電氣設備配備滿足設計方案規(guī)定;路線無絕緣脆化和拓寬。
4. The wiring of electrical equipment in movable board room shall be PVC pipe (slot), and the wiring shall be neat and beautiful; The allocation of electrical equipment shall meet the provisions of the design scheme; The route has no insulation embrittlement and widening.
5.活動板房的阻燃性:距離應滿足設計方案和標準規(guī)定,消防通道門應順暢;消防栓和消防滅火器配置滿足設計方案規(guī)定,合理布局;餐廳廚房等火災事故場地的阻燃隔熱保溫舉措應合理;金屬材料彩鋼夾芯板的阻燃等級不可小于32,木地板等易燃原材料應做好阻燃解決。
5. Fire resistance of movable plank house: the safety distance shall meet the design scheme and standard provisions, and the fire access door shall be smooth; The configuration of fire hydrants and fire extinguishers shall meet the provisions of the design scheme, and the layout shall be reasonable; Fire retardant and thermal insulation measures for fire accident sites such as restaurants and kitchens shall be reasonable; The flame retardant grade of metal material color steel sandwich board shall not be less than 32, and the flame retardant of wood floor and other flammable raw materials shall be solved.
6.活動板房避雷:防雷及接地設定合乎設計方案及標準規(guī)定;接地線電阻應檢測達標。
6. Lightning protection of movable plank house: the lightning protection and grounding settings comply with the design scheme and standards; The resistance of grounding wire shall meet the standard.
以上就是為大家介紹的全部內容,希望對大家有所幫助。如果您想要了解更多的知識,您可以瀏覽我們的網站,我們會為您提供更詳細的信息。也可以給我們電話聯(lián)系,我們將24小時為您提供在線服務。
The above is all the content introduced to you. I hope it will be helpful to you. If you want to know more, you can visit our website and we will provide you with more detailed information. You can also call us and we will provide you with online service 24 hours a day.