活動(dòng)房的布局是很有講究的,不是隨隨便便就可以搭建的。安徽活動(dòng)房廠家今天來(lái)與您分享一些活動(dòng)房布局時(shí)的注意事項(xiàng),希望對(duì)您起到一些幫助。
The layout of the activity room is very particular, which can not be built casually. Anhui mobile house manufacturers are here today to share with you some precautions for the layout of mobile houses, hoping to help you.
1、活動(dòng)房圍護(hù)板材(屋面板和墻板)應(yīng)無(wú)明顯變形、損壞;固定螺栓、防水墊圈、金屬墊圈、尼龍?zhí)坠艿三R全,連接可靠;密封膠齊全。
1. The enclosure plate (roof panel and wall panel) of the movable room shall be free from obvious deformation and damage; Fixing bolts, waterproof washers, metal washers, nylon sleeves, etc. are complete and connected reliably; Sealant is complete.
2、活動(dòng)房屋面板應(yīng)安裝平穩(wěn)、檐口平直,板的搭接方向正確一致。
2. The panel of movable house shall be installed stably, the cornice shall be straight, and the overlapping direction of the panel shall be correct and consistent.
3、附著式墻板安裝應(yīng)排板正確,表面平整;嵌入式墻板安裝應(yīng)平整,上下搭接縫應(yīng)采用企口縫,外側(cè)板應(yīng)向下搭接,搭接長(zhǎng)度不小于15mm。
3. The attached wallboard shall be installed with correct plate arrangement and flat surface; The installation of embedded wallboard shall be flat, the upper and lower lap joints shall adopt tongue and groove joints, and the outer panel shall be lapped downward, and the lap length shall not be less than 15mm.
4、活動(dòng)房?jī)?nèi)電器線路應(yīng)采用PVC管(槽)明敷,布線整齊美觀;電器配置符合設(shè)計(jì)要求;線路無(wú)絕緣老化及接長(zhǎng)使用。
4. The electrical circuit in the activity room shall be laid in PVC pipe (slot) in an open manner, and the wiring shall be neat and beautiful; The electrical configuration meets the design requirements; The line is free of insulation aging and extension.
5、防火:防火間距應(yīng)符合設(shè)計(jì)和規(guī)范要求,消防通道應(yīng)通暢;消火栓、滅火器配置符合設(shè)計(jì)要求,布局合理;廚房等用火場(chǎng)所防火隔熱措施應(yīng);金屬面夾芯板氧指數(shù)不低于32,木地板等可燃材料應(yīng)做防火處理。
5. Fire prevention: the fire prevention spacing shall meet the design and specification requirements, and the fire passage shall be unobstructed; The configuration of fire hydrants and fire extinguishers meets the design requirements and the layout is reasonable; Fire prevention and thermal insulation measures for kitchen and other fire sites shall be; The oxygen index of metal faced sandwich panel shall not be lower than 32, and combustible materials such as wood floor shall be subject to fire prevention treatment.
6、防雷:防雷接地設(shè)置符合設(shè)計(jì)和規(guī)范要求;接地電阻應(yīng)檢測(cè)合格。
6. Lightning protection: the lightning protection and grounding settings meet the design and specification requirements; The grounding resistance shall pass the test.
7、防腐:鋼構(gòu)件應(yīng)油漆完好、無(wú)銹蝕,外露螺栓防護(hù)得當(dāng);強(qiáng)腐蝕環(huán)境下的防腐措施符合設(shè)計(jì)要求;活動(dòng)房周邊應(yīng)排水通暢,無(wú)積水,不準(zhǔn)放雜物。
7. Anti corrosion: steel members shall be painted in good condition without corrosion, and exposed bolts shall be properly protected; The anti-corrosion measures in strong corrosive environment meet the design requirements; The periphery of the activity room shall be drained smoothly without ponding and sundries are not allowed.
The wonderful content of this article is provided by Jinan Caigang plank house. There are many wonderful contents on this website. You can click to enter more contents: http://hxwjw.org.cn We have special customer service to answer your questions